Method Name
A short description of the method used to perform the test
NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Yes
Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test
Pigeon/Dove Droppings Gel Diffusion
Specimen Type
Describes the specimen type validated for testing
Serum
Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing
Specimen Type: Serum
Container/Tube: Red or SST
Specimen Volume: 0.5 mL
Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube(s) is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.
Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
Specimen Type |
Temperature |
Time |
Special Container |
Serum |
Refrigerated (preferred) |
28 days |
|
|
Ambient |
28 days |
|
|
Frozen |
28 days |
|
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
Interpretation
Provides information to assist in interpretation of the test results
The gel diffusion method was used to test this patient's serum for the presence of precipitating antibodies (IgG) to the antigens indicated. These antibodies are serological markers for exposure and immunological sensitization. The clinical significance varies, depending on the history and symptoms.
PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information
No
Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
7 to 14 days
Eurofins Viracor
Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
- Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
This test was developed and its performance characteristics determined by Eurofins Viracor. It has not been cleared or approved by the U.S. Food and Drug Administration.
Test Id |
Test Order Name |
Order LOINC Value
|
FPDD |
Pigeon/Dove Droppings Gel Diffusion |
24505-0 |
Result Id |
Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
Z5608 |
Pigeon/Dove Droppings Gel Diffusion |
24505-0 |