Test Catalog

Test Id : APOAB

Apolipoprotein A1 and B, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Assessment of cardiovascular risk

 

Follow-up studies in individuals with basic lipid measures inconsistent with risk factors or clinical presentation

 

Definitive studies of cardiac risk factors in individuals with significant family histories of coronary artery disease or other increased risk factors

Profile Information
A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test Id Reporting Name Available Separately Always Performed
RBAA1 Apolipoprotein B/A1 ratio No Yes
APOA1 Apolipoprotein A1, S Yes Yes
APOLB Apolipoprotein B, S Yes Yes

Method Name
A short description of the method used to perform the test

Automated Turbidimetric Immunoassay

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Apolipoprotein A1 and B, S

Aliases
Lists additional common names for a test, as an aid in searching

APOAB

Apo A

Apo A-I

Apo A1

Apo Al

Apo B

ApoA

ApoA-I

ApoA1

ApoAl

ApoB

Apolipoprotein A

Apolipoprotein A-I

Apolipoprotein A1

Apolipoprotein A1 and B-100, Plasma

Apolipoprotein AI

Apolipoprotein B

Apolipoprotein B-100

Apolipoprotein B/A1 ratio

Apolipoprotein B100

RBAA1

Specimen Type
Describes the specimen type validated for testing

Serum

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot 1 mL of serum.

Forms

If not ordering electronically, complete, print, and send a Cardiovascular Test Request Form (T724) with the specimen.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

0.5 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia OK
Gross icterus Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 8 days
Frozen 60 days
Ambient 24 hours

Useful For
Suggests clinical disorders or settings where the test may be helpful

Assessment of cardiovascular risk

 

Follow-up studies in individuals with basic lipid measures inconsistent with risk factors or clinical presentation

 

Definitive studies of cardiac risk factors in individuals with significant family histories of coronary artery disease or other increased risk factors

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Apolipoprotein B (ApoB) is the primary protein component of low-density lipoprotein (LDL). Apolipoprotein A1 (ApoA1) is the primary protein component of high-density lipoprotein (HDL). Elevated ApoB and decreased ApoA1 are associated with increased risk of cardiovascular disease. Multiple studies have reported that ApoB and ApoA1 are more strongly associated with cardiovascular disease than the corresponding lipoprotein cholesterol fraction (see APOA1 / Apolipoprotein A1, Serum and APOLB / Apolipoprotein B, Serum).

 

ApoB is present in all atherogenic lipoproteins including LDL, Lp(a), intermediate-density lipoprotein (IDL), and very low-density lipoprotein (VLDL) remnants. ApoA1 is the nucleating protein around which HDL forms during reverse cholesterol transport. The ApoB:ApoA1 ratio represents the balance between atherogenic and antiatherogenic lipoproteins. Several large prospective studies have shown that the ApoB:ApoA1 ratio performs as well, and often better, than traditional lipids as an indicator of risk.(1-3)

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Males

Age

Apolipoprotein A (mg/dL)

Apolipoprotein B (mg/dL)

Apolipoprotein B/A1 ratio

<24 months

Not established

Not established

Not established

2-17 years

Low: <115

Borderline low: 115-120

Acceptable: >120

Acceptable: <90

Borderline high: 90-109

High: > or =110

<0.8

>18 years

> or =120

Desirable: <90

Above Desirable: 90-99

Borderline high: 100-119

High: 120-139

Very high: > or =140

 

Lower Risk: <0.7

Average Risk: 0.7-0.9

Higher Risk: >0.9

Females

Age

Apolipoprotein A (mg/dL)

Apolipoprotein B (mg/dL)

Apolipoprotein B/A1 ratio

<24 months

Not established

Not established

Not established

2-17 years

Low: <115

Borderline low: 115-120

Acceptable: >120

Acceptable: <90

Borderline high: 90-109

High: > or =110

<0.8

>18 years

> or =140

Desirable: <90

Above Desirable: 90-99

Borderline high: 100-119

High: 120-139

Very high: > or =140

 

Lower Risk: <0.6

Average Risk: 0.6-0.8

Higher Risk: >0.8

Interpretation
Provides information to assist in interpretation of the test results

Elevated apolipoprotein B (ApoB) confers increased risk of atherosclerotic cardiovascular disease, even in a context of acceptable LDL cholesterol concentrations.

 

Extremely low values of ApoB (<48 mg/dL) are related to malabsorption of food lipids and can lead to polyneuropathy.

 

Reduced apolipoprotein A1 (ApoA1) confers an increased risk of coronary artery disease. Extremely low ApoA1 (<20 mg/dL) is suggestive of liver disease or a genetic disorder.

 

Elevated ApoB:ApoA1 ratio confers increased risk of atherosclerotic cardiovascular disease, independently of LDL and HDL cholesterol concentrations.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

In very rare cases, gammopathy, in particular type IgM (Waldenstrom macroglobulinemia), may cause unreliable results.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Reiner Z, Catapano AL, De Backer G, et al: ESC/EAS Guidelines for the management of dyslipidaemias: The task force for the management of dyslipidaemias of the European Society of Cardiology (ESC) and the European Atherosclerosis Society (EAS). Eur Heart J 2011;32(14):1769-1818

2. McQueen MJ, Hawken S, Wang X, et al: Lipids, lipoproteins, and apolipoproteins as risk markers of myocardial infarction in 52 countries (the INTERHEART study): a case-control study. Lancet 2008;372:224-233

3. Thompson A, Danesh J: Associations between apolipoprotein B, apolipoprotein AI, the apolipoprotein B/AI ratio and coronary heart disease: a literature-based meta-analysis of prospective studies. J Intern Med 2006;259:481-492

4. Jacobson TA, Ito MK, Maki KC, et al: National Lipid Association recommendations for patient-centered management of dyslipidemia: Part 1-executive summary. J Clin Lipidol 2014 Sep-Oct;8(5):473-488

5. Expert panel on integrated guidelines for cardiovascular health and risk reduction in children and adolescents: summary report. Pediatrics 2011 Dec;128 Suppl 5:S213-S256

Method Description
Describes how the test is performed and provides a method-specific reference

Antiapolipoprotein B antibodies react with the antigen in the sample to form antigen:antibody complexes which, following agglutination, can be measured turbidimetrically.(Package Insert: Tina-quant Apolipoprotein B, Roche Diagnostics. Indianapolis, IN. 05/2019)

 

Antiapolipoprotein A-1 antibodies react with the antigen in the sample to form antigen:antibody complexes which, following agglutination, can be measured turbidimetrically.(Package Insert: Tina-quant Apolipoprotein A-1, Roche Diagnostics. Indianapolis, IN. 05/2019)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

APOA1: Monday through Sunday

APOLB: Monday through Saturday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 3 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

1 week

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

82172 x 2

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
APOAB Apolipoprotein A1 and B, S 55724-9
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
APOLB Apolipoprotein B, S 1884-6
APOA1 Apolipoprotein A1, S 1869-7
RBAA1 Apolipoprotein B/A1 ratio 1874-7

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports