Technical interpretation of inhibitor to factor IX testing for patients with hemophilia B
Only orderable as part of a profile. For more information see 9INHE / Factor IX Inhibitor Evaluation, Plasma.
Technical Interpretation
Factor IX Inhibitor Profile
Factor IX Inhibitor Screen, Plasma
Plasma Na Cit
Only orderable as part of a profile. For more information see 9INHE / Factor IX Inhibitor Evaluation, Plasma.
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Technical interpretation of inhibitor to factor IX testing for patients with hemophilia B
Factor IX inhibitors arise in patients with severe hemophilia B after factor IX transfusion. Patients with factor IX inhibitors may also develop anaphylactic reactions in response to factor IX infusions. Acquired factor IX inhibitors, occurring in previously healthy people, are exceedingly rare.
Only orderable as part of a profile. For more information see 9INHE / Factor IX Inhibitor Evaluation, Plasma.
An interpretive report will be provided.
When testing is complete, if factor activity results fall within clinically normal ranges, an interpretive comment will be provided noting that inhibitor testing was not indicated and, therefore, not performed. If factor activity indicates the performance of inhibitor screen testing, an interpretive comment will be provided noting the presence or absence of a factor IX inhibitor.
Occasionally, a potent lupus-like anticoagulant may cause false-positive testing for a specific factor inhibitor (eg, factor VIII or IX).
2. Chitlur M, Warrier I, Rajpurkar M, et al. Inhibitors in factor IX deficiency a report of the ISTH-SSC international FIX inhibitor registry (1997-2006). Haemophilia. 2009;15(5):1027-1031
If the factor IX activity level is normal or elevated, a computer-generated interpretive comment indicating inhibitor testing was not indicated and was not performed will be provided.(Unpublished Mayo method)
Monday through Friday
Not Applicable
85390
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
9INHT | FIX Inhib Profile Tech Interp | 69049-5 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
9INHT | FIX Inhib Profile Tech Interp | 69049-5 |