Test Catalog

Test Id : DLL3

Delta-Like 3 Protein (SP347), Semi-Quantitative Immunohistochemistry, Manual, Tissue

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnosis of small cell lung carcinoma (SCLC), large cell neuroendocrine carcinoma (LCNEC), amongst other tumors

Method Name
A short description of the method used to perform the test

Immunohistochemistry (IHC)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

DLL3(SP347)Semi-Quant IHC,Manual

Aliases
Lists additional common names for a test, as an aid in searching

DLL3

SP347

Specimen Type
Describes the specimen type validated for testing

Special

Shipping Instructions

Attach the green "Attention Pathology" address label (T498) and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.

Necessary Information

A pathology/diagnostic report and a brief history are required.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Specimen Type: Tissue

Supplies:

-Pathology Packaging Kit (T554)

-Immunostain Technical Only Envelope (T693)

Container/Tube: Immunostain Technical Only Envelope

Collection Instructions: Formalin-fixed, paraffin-embedded tissue block; or 3 unstained glass, “positively charged” slides with 4-microns, formalin-fixed, paraffin-embedded tissue

Additional Information: One slide will be stained with hematoxylin and eosin and returned.

Forms

If not ordering electronically, complete, print, and send a Immunohistochemical (IHC)/In Situ Hybridization (ISH) Stains Request (T763) with the specimen.

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Wet/frozen tissue
Cytology smears
Nonformalin fixed tissue
Nonparaffin embedded tissue
Noncharged slides
ProbeOn slides
Reject
 

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Special Ambient (preferred)
Refrigerated

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnosis of small cell lung carcinoma (SCLC), large cell neuroendocrine carcinoma (LCNEC), amongst other tumors

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Delta-like 3 protein (DLL3) is an atypical Notch ligand induced by the neuroendocrine transcription factor, ASCL-1.  DLL3 is expressed on the cell membrane and in the cytoplasm of tumor cells. 

Interpretation
Provides information to assist in interpretation of the test results

Positivity for this test will require 50% or more of the tumor cells within a specimen to express delta-like 3 protein with an intensity ranging from 1 to 3+.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

This test has been validated for non-decalcified paraffin embedded tissue specimens fixed in 10% neutral buffered formalin. This assay has not been validated on tissues subjected to the decalcification process and/or use of alternative fixatives for bone/bone marrow specimens or cell blocks.

 

Age of a cut paraffin section can affect immunoreactivity. Stability thresholds vary widely among published literature and are antigen dependent. Best practice is for paraffin sections to be cut within 6 weeks.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Saunders LR, Bankovich AJ, Anderson WC, et al. A DLL3-targeted antibody-drug conjugate eradicates high-grade pulmonary neuroendocrine tumor-initiating cells in vivo. Sci Transl Med. 2015;7(302):302ra136

2. Xie H, Boland JM, Maleszewski JJ, et al. Expression of delta-like protein 3 is reproducibly present in a subset of small cell lung carcinomas and pulmonary carcinoid tumors. Lung Cancer. 2019;135:73-79. doi:10.1016/j.lungcan.2019.07.016

3. Xie H, Kaye FJ, Isse K, et al. Delta-like protein 3 expression and targeting in merkel cell carcinoma. Oncologist. 2020;10:810-817. doi:10.1634/theoncologist.2019-0877

4. Magaki S, Hojat SA, Wei B, So A, Yong WH. An introduction to the performance of immunohistochemistry. Methods Mol Biol. 2019;1897:289-298. doi:10.1007/978-1-4939-8935-5_25

Method Description
Describes how the test is performed and provides a method-specific reference

Immunohistochemistry on sections of paraffin-embedded tissue.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

5 to 7 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

Until reported

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

88360

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
DLL3 DLL3(SP347)Semi-Quant IHC,Manual In Process
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
603333 Interpretation 59465-5
603334 Participated in the Interpretation No LOINC Needed
603335 Report electronically signed by 19139-5
603336 Material Received 81178-6
603337 Disclaimer 62364-5
603338 Case Number 80398-1

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports